Problem
Commit template failed due to the device being out of sync.
-----------------------------------------------------------------------------
Solution
Commit works only if the appliance configuration is synced with Versa Director.
If there are any modifications done via appliance CLI, it leads to the “out-of-sync” mode in Versa Director for the appliance. If you try to commit a template to the device which is out of sync, it will fail.
To check the config difference, click on Compare config with Appliance icon.
If you require to retain the changes which is done from the CLI, you can use, sync-config-from-appliance.
Else use you can use “sync-config-to-appliance”, here the appliance configuration from Versa Director will get synced with the device and CLI changes will be wiped off.
Once the device is in full sync, you can commit the template to the device.